How to resolve MIB dependencies (load order) with custom MIBs.
The following symptoms in the up.time MIBBrowser are signs that there is an issue with the order that custom MIBs are being loaded from the <uptime_dir>/mibs/ directory:
To verify that this is the issue (and to identify the offending MIB), look in the thirdparty.log file located in the <uptime_dir>/logs directory and look for errors such as:
2012-06-11 11:35:21,833 ERROR [Webserver-32 - /uptime/snmp/getMibTree] (Log4jImpl:36) - MIB loaded from reader contains unknown mib imports: ibDHCPOne.
The corresponding MIB needs to be loaded beforehand or it should be in the same directory as current MIB 2012-06-11 11:35:21,852 ERROR [Webserver-32 - /uptime/snmp/getMibTree] (Log4jImpl:36) - MIB loaded from reader contains unknown mib imports: ibDHCPServ. Note that you may see some warnings in the thirdparty.log file similar to the messages below but these are not cause for concern:
2012-06-12 14:35:35,699 ERROR [Webserver-23 - /uptime/snmp/getMibTree] (Log4jImpl:36) - Unknown snmp data type: [APPLICATION.
The corresponding MIB need to be placed in the same directory or loaded beforehand.
The sample errors listed above indicate that the ibDCHPOne & ibDHCPServ MIBs failed to load because they were missing some of their imports.
To resolve this issue, open the MIB that failed to load from the <uptime_dir>/mibs/ directory and look at the imports section near the top. For example, from the ibDHCPOne sample in the error above:
IMPORTS
OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
Counter64, Unsigned32 FROM SNMPv2-SMI
Counter FROM RFC1155-SMI
ibDHCPOne, IbString, IbIpAddr FROM IB-SMI-MIB;
In this example, IB-SMI-MIB is a non-bundled MIB and the source of the import issues because it was not properly loaded before the ibDHCPOne tried to import values from it.
Now that we have identified which MIB contains the missing import values, we need to re-name the file in the <uptime_dir>/mibs/ directory so that up.time will load that one before the others. The MIB files are loaded in alphanumeric order (i.e. 0 - 9 then A - Z then a - z). So, using the examples above, they were originally named:
IB-DHCPONE-MIB.mib IB-SMI-MIB.mib
Re-named to:
03000-IB-SMI-MIB.mib
03001-IB-DHCPONE-MIB.mib
After re-naming the files, restart the uptime_core/data collector services on the monitoring station, which will cause up.time to clear it's cached MIBs from memory. Then set up a new SNMP Poller monitor, and click the Add OID button, which will reload the MIBs into memory in the new order. Once these are loaded into memory again, you should also now be able to fully drill down to the OID in question in the MIB browser. Checking the thirdparty.log file again should also no longer have errors about missing imports for the MIB. |
Why is up.time server load so high at the start of the month? | Rating | Views | |
---|---|---|---|
![]() |
At the start of each month the up.time data archiving process initiates to clear out old data from your DataStore. This can be a very resource heavy operation and may take a great deal of time to... By: uptime Support | Date Created: 8-7-2010 | Last Modified: 8-10-2011 | Index: 469 |
![]() ![]() ![]() ![]() ![]() |
2313 |
SNMP monitor applet won't load | Rating | Views | |
---|---|---|---|
![]() |
The SNMP monitor uses a java based applet to browse and select OIDs from available MIB files. On some browsers you may find that the applet fails to load, which makes the browser window appear as... By: uptime Support | Date Created: 8-13-2010 | Last Modified: 8-13-2011 | Index: 483 |
![]() ![]() ![]() ![]() ![]() |
1991 |
Unable to Add ESX Server to up.time 5.x | Rating | Views | |
---|---|---|---|
![]() |
There are several possible reasons why you may be experiencing this issue. To help identify the root cause, take the following steps: 1. Try using Root credentials to add the ESX host by its... By: uptime Support | Date Created: 6-9-2011 | Last Modified: 8-12-2011 | Index: 525 |
![]() ![]() ![]() ![]() ![]() |
2849 |
SNMP service monitor fails to load | Rating | Views | |
---|---|---|---|
![]() |
Symptom: When trying to add an SNMP service monitor, the applet does not load and generates the following error: Java Plug-in 1.6.0_23 Using JRE version 1.6.0_23-b05 Java HotSpot(TM) Client VM... By: uptime Support | Date Created: 7-12-2011 | Last Modified: 8-11-2011 | Index: 546 |
![]() ![]() ![]() ![]() ![]() |
2206 |
Monitoring HTTP Services in a Load Balanced Cluster | Rating | Views | |
---|---|---|---|
![]() |
To monitor the web site available on your load balanced cluster we reccomend this approach. 1 - Install the up.time agent on each of your cluster nodes and monitor them with up.time. This will... By: uptime Support | Date Created: 12-31-1969 | Last Modified: 8-31-2011 | Index: 295 |
![]() ![]() ![]() ![]() ![]() |
3225 |